Single-use manifolds for bioprocessing are rarely off-the-shelf parts: each assembly has to match its process’s tubing, connector types and fluid routing. Elcam Medical adapts manifold designs proven in disposable medical devices into Bio-Manifolds for bioprocess applications, with built-in barb connections that can replace separate adaptors. For integrators and CDMOs, that means fewer parts and assembly steps, and a supplier that engineers around the application.
System integrators and CDMOs need more than off-the-shelf components. They need suppliers with the engineering expertise and flexibility to adapt designs to specific fluid-path and assembly requirements.
In bioprocess single-use technology (SUT), applications like monoclonal antibody production, vaccine manufacturing, and cell and gene therapy (CGT) each bring their own design challenges. Teams need to consider tubing dimensions, connector types, fluid routing, and compatibility with existing bioreactors, sampling assemblies, and fluid-transfer systems.
Standard components offer a starting point, but they don’t always fit application requirements as-is.
Why Single-Use Bioprocess Assemblies Need Custom Components
Close engineering collaboration helps teams define specific requirements, explore design alternatives, and develop configurations that get the job done.
As a June 2026 Lab Design News article on single-use facility design explains, “Single-use manifolds are not standard, off-the-shelf products. They are custom-designed assemblies, unique to each facility’s process requirements.”
Meeting specific requirements doesn’t have to mean starting from scratch. Existing component designs can provide a solid foundation, with targeted modifications to meet the needs of a particular bioprocess application.
The right bioprocess supplier may not come from the bioprocess industry at all. Manufacturers of single-use medical devices already have proven systems in place to customize designs and scale up manufacturing as needed.
How Built-In Barb Connections Reduce Parts and Assembly Steps

Connector compatibility is one area where custom engineering can make a real difference.
Small engineering changes can make fluid-path assemblies much simpler. Drawing on more than 50 years of experience working with medical-device OEMs, Elcam Medical shows how that expertise transfers by adapting its proven manifold designs, used in a wide range of clinical settings, to create Bio-Manifolds specifically for bioprocess applications.
Michael Segev, Elcam’s Chief Business Officer, says, “By adapting our manifolds with built-in barb connections instead of Luer connectors, we can eliminate seven separate adaptors in one configuration, reducing the number of parts and assembly steps for the integrator.”
Working with a Supplier from Requirements to Production
Connector compatibility is just one piece of the puzzle. Designing single-use fluid paths also involves planning for tubing lengths, fluid routing, connector placement, and cleaning and flushing sequences. Working through these requirements, reviewing supplier drawings, and securing approvals can take six to nine months—or longer—when starting from scratch, according to the same Lab Design News article.
Early collaboration gives engineering teams time to work through these challenges together and get the design right from the start.
Elcam draws on its medical-device engineering experience to help shape component designs early, bringing together engineers from different disciplines to work through application requirements and plan for full-scale manufacturing. As Segev says, “We can work directly with integrators and CDMOs to understand their requirements, develop application-specific solutions, and bring those designs into production.”
Choosing a Single-Use Component Partner for Bioprocess
Choosing a component supplier isn’t just about finding the right parts in a catalog. It’s about finding a partner you can count on as your needs grow and change, with the expertise and flexibility to tackle new challenges together.
With its new Bioprocess Family, Elcam is extending its single-use component portfolio into bioprocessing, backed by established expertise, advanced manufacturing, and supply-chain capabilities. “We’re bringing new engineering ideas to bioprocess and looking to collaborate with integrators and CDMOs on the component designs their applications require,” says Segev.
Frequently Asked Questions
What is a single-use manifold in bioprocessing?
A single-use manifold is a flow-control component within a single-use bioprocess assembly. Manifolds are usually custom-designed for each facility’s process requirements, because tubing dimensions, connector types and fluid routing differ from one application to the next.
What are Elcam Bio-Manifolds?
Bio-Manifolds are Elcam’s customizable flow solutions, designed to streamline single-use bioprocess assemblies. They come in multiple configurations, including 2–5 ports, Luer connections, and 1/8” or 3/16” barb options, with a choice of handle types, colors and raw materials such as polysulfone and polycarbonate.
Why use barb connections instead of Luer connectors in a bioprocess assembly?
Barb connectors match the most common tubing formats used in bioprocess applications. Building the barb into the component removes the need for separate Luer-to-barb adaptors, which makes assembly simpler. In one Elcam configuration, it eliminates seven separate adaptors.
How long does it take to design a single-use manifold assembly?
Working through the requirements, reviewing supplier drawings and securing approvals can take six to nine months or longer when starting from scratch. Starting from an existing, proven component design and involving the supplier early gives engineering teams time to get the design right from the start.
What does the Elcam Bioprocess Family include?
The Elcam Bioprocess Family is a portfolio of single-use components for fluid handling, flow control, closed access, secure connections and pressure monitoring in bioprocess applications. It includes Bio-Manifolds, Bio-Flow Valves, Bio-NIP® NeedleFree Connectors, Bio-Safe2™ Rotators and Bio-P-Sensor™ single-use pressure sensors.
Have a fluid-path challenge or a component that needs adapting? Get in touch with Elcam to discuss your requirements and explore the possibilities.
Elcam Bioprocess